DISPENSER REPAIRS
We support all Corob, Fluid Management and Ital Tinto dispensers.
![](https://static.wixstatic.com/media/5f02d4_3f5c31c77a4f4b0b860f6f4cb29d20cc.jpg/v1/fill/w_600,h_280,al_c,q_80,usm_0.66_1.00_0.01,enc_avif,quality_auto/5f02d4_3f5c31c77a4f4b0b860f6f4cb29d20cc.jpg)
![](https://static.wixstatic.com/media/5f02d4_e8acfbda44844762ba35ed98e7e9f21e.jpg/v1/fill/w_370,h_377,al_c,q_80,usm_0.66_1.00_0.01,enc_avif,quality_auto/5f02d4_e8acfbda44844762ba35ed98e7e9f21e.jpg)
![](https://static.wixstatic.com/media/5f02d4_8bce12267e754275902faec9440988c8.jpg/v1/fill/w_292,h_377,al_c,q_80,usm_0.66_1.00_0.01,enc_avif,quality_auto/5f02d4_8bce12267e754275902faec9440988c8.jpg)
If a formula is not coming out accurately there are only two possibilities - either the formula is off or the dispense is off. An inaccurate dispense can be caused by a clogged intake or by a defective pump. To diagnose take some small cups and compare dispenses between colorants. The dispense volume should be the same between colorants.